holder

ATTENTION: This site is down for maintenance in read-only mode.

The following is an abstract for the selected article. A PDF download of the full text of this article is available here. Members may download full texts at no charge. Non-members may be charged a small fee for certain articles.


Application of Magnetic Resonance Imaging to the Investigation of the Diffusivity of 1,1,1,2-Tetrafluorethane in Two Polymers

Volume 58, Number 3 (March 2004) Page 338-343

Mayele, M.; Oellrich, L.R.


In order to evaluate the suitability of a polymer as a sealing material for certain working fluids used in process plants, information about the fluid diffusivity into the polymer or the polymer permeability to the fluid is a prerequisite. The fluid of interest in the present work is 1,1,1,2-tetrafluorethane, CH2FCF3, a partly fluorinated hydrocarbon (HFC) commonly known as refrigerant R134a. HFCs are increasingly used in refrigeration, air conditioning, and heat pump applications as substitutes for the chlorofluorocarbons (CFCs) or hydrochlorofluorocarbons (HCFCs) that are believed to be responsible for ozone depletion in the stratosphere. The polymers studied were FPM, a perfluoroelastomer, and EPDM, an ethylene-propylene-diene rubber. The study was carried out using magnetic resonance imaging (MRI). The contact time dependence of diffusion of the fluid into the polymer, as well as the spatial distributions of spin-lattice, T1, and spin-spin, T2, relaxation times, were used as indicators of the influence of the EPDM matrix on the mobility of R134a molecules.