holder

The following is an abstract for the selected article. A PDF download of the full text of this article is available here. Members may download full texts at no charge. Non-members may be charged a small fee for certain articles.


Laser-Induced Breakdown Spectroscopy for On-Line Engine Equivalence Ratio Measurements

Volume 57, Number 9 (Sept. 2003) Page 1183-1189

Ferioli, Francesco; Puzinauskas, Paulius V.; Buckley, Steven G.


Laser-induced breakdown spectroscopy (LIBS) has been used to measure the equivalence ratio of a spark-ignited engine in a laboratory setting. Spectral features of C (711.3 nm), O (776.6 nm), N (746.3 and 743.8 nm), and CN (broad emission 707-734 nm) were used to quantify the equivalence ratio over a range from Φ = 0.8 to Φ = 1.2. The C/N and C/O peak ratios were found to be successful measurement metrics, compared with a standard exhaust gas oxygen analyzer, for averaged measurements. Some variation in the measurements was observed as a function of engine load. Single-shot data based on a CN/air peak ratio were evaluated using a separate calibration from averaged measurements, and the average of the single-shot data was found to agree well with the exhaust gas oxygen analyzer. The scatter in the single-shot data was substantially higher at lower equivalence ratios. The measurements including the CN peak were slightly sensitive to load, possibly due to pressure changes in the sample as the load increases, or possibly due to changes in the particle size distribution in the gas stream.